Skip to content
PLTS Paket A on-grid rooftop solar overview with daytime bill savings and system flow

On-grid rooftop — BK-PLTS-A

Most requested

PLTS Paket A — Solar Savings

Grid-tied rooftop solar that cuts daytime operating costs by 20–40%.

A grid-tied PV system for factories, warehouses, distribution centres, and commercial buildings that already have a reliable PLN supply. Solar offsets the daytime load; the grid stays as the backup.

Free load study25-year panel warrantyIndonesia-wide

20–40%

Daytime bill reduction

25 yrs

Panel performance warranty

PLN

Grid stays as backup

0

Fuel or battery upkeep

The package

What Paket A
is built for.

Paket A is the most direct way to reduce a daytime electricity bill. The array is sized to your daytime base load, so most of what the modules produce is consumed on site instead of exported.

Because the system stays connected to PLN, there is no battery to maintain and no change to how the building runs. The inverter synchronises with the grid, and anti-islanding protection disconnects the array during an outage so maintenance crews stay safe.

A typical factory or warehouse sees a 20–40% reduction in monthly PLN charges depending on roof area, irradiance, and the share of load that runs between 08:00 and 17:00. A free load study confirms the offset before any equipment is ordered.

Best for

  • Factory
  • Warehouse
  • Distribution centre
  • Commercial building
  • Residential estate

At a glance

  • — On-grid topology — PLN remains the backup
  • — Roof or ground mount
  • — String inverter with anti-islanding protection
  • — Remote monitoring included

What is included

Everything in the
Paket A package.

  • — Tier-1 monocrystalline PV modules
  • — On-grid string inverter with anti-islanding
  • — Galvanised roof or ground mounting structure
  • — DC/AC protection, earthing, and surge devices
  • — Revenue-grade production monitoring
  • — Installation, commissioning, and as-built documents

Final capacity, Bill of Materials, and price are confirmed after the free technical feasibility study. No payment is taken on this page.

Scale check

What 1 kW to 1 MW looks like.

This is the same sizing instrument used across the PLTS family, pre-set to the load profile that suits Paket A.

Sizing instrument

From 1 kW to 1 MW.

Pick a load profile, then move along the rail. Each setting shows the PV array, usable battery, module count, inverter count, and mounting area you would expect for that scale.

Indicative pre-feasibility

Factories, warehouses, offices

100 kWp

Indicative design

100 kWp

Daytime profile · 8 h/day

Usable BESS
120 kWh
Load served
42 kW
Send this sizing on WhatsApp →
Daily generation
336 kWh
Load served
42 kW
Usable BESS
120 kWh
650 Wp modules
154 units
Inverters
2 × 50 kW
Mounting area
400 m²
Annual yield
123 MWh
CO₂ avoided
107 t/yr

Indicative only: 4.2 peak-sun hours per day, 80% performance ratio, 650 Wp modules at 2.6 m² each including access, tiered string inverters, and a 0.87 t CO₂/MWh grid factor. A measured load study sets the final design.

100 kilowatt peak, Daytime profile, 120 kilowatt-hour battery, 154 modules, 2 inverters.

The common standard

Every package is engineered, not assembled.

Each Bamantara PLTS package starts with a load study and a single-line electrical design. Tier-1 monocrystalline modules, IEC/SNI protection, structural mounting, commissioning, and remote monitoring are included as standard. The final scope and price are confirmed after a free site survey — no estimate on this page replaces a stamped design.

  • — Load study and single-line electrical design before pricing
  • — Tier-1 monocrystalline modules with a 25-year performance warranty
  • — IEC/SNI protection, earthing, and surge devices
  • — Structural mounting designed for local wind and roof loads
  • — Commissioning, as-built documentation, and remote monitoring
  • — Free site survey and technical feasibility study across Indonesia

FAQ

Questions about Paket A.

What size PLTS does a factory need?
Start from the daytime load, not the building area. In Indonesia, a 100 kWp array typically serves roughly 40–45 kW of continuous daytime load at our 4.2 peak-sun-hour assumption. We confirm the real number with a 15-minute interval load study before sizing.
What happens during a PLN outage?
A standard on-grid inverter shuts down for safety, so the building does not back-feed the grid. If you need power during outages, Paket B adds battery storage and a hybrid inverter.
How long does installation take?
Most rooftop systems under 100 kWp are installed in two to four weeks after approval. Larger arrays are phased so operations keep running during the works.
Does Paket A support PLN net metering?
Yes. We register the system with PLN and configure export limitation where net metering is capped, so the design stays compliant with your connection agreement.

Send the load.
We will size the plant.

Share your site, load profile, and operating hours. Our engineers will return a technical feasibility study and a Paket A recommendation.